Gas water heaters companies Electrolux are in demand all over the world, but even the best quality equipment sooner or later has to be repaired. Most often, troubleshooting a geyser Electrolux even those who have no experience in the field of repair can do it.
It wouldn’t be bad to fix the column yourself and save on calling a repairman, wouldn’t it? But how to diagnose the cause of the breakdown and what to do next? We will talk about all this in this publication - we will consider the popular malfunctions of the Electrolux brand gas water heater, the procedure for determining the cause and methods for restoring performance. For clarity, we will provide the article with photos and thematic videos.
The content of the article:
Review of popular column faults
Gas water heaters of the Electrolux brand are highly reliable, but their owners also face a number of problems, which we will discuss in more detail. Some of them can be diagnosed and fixed on your own, but to repair certain breakdowns you will need to contact specialists. For self-diagnosis, home craftsmen will come to the aid of the manufacturer’s instructions, which come with any geyser.
Now let's talk about popular malfunctions, possible causes of their occurrence and methods of elimination.
Problem #1 - the speaker does not turn on
If your Electrolux household gas water heater does not turn on, do not rush to urgently call a technician. To begin with, you can try to determine the cause yourself.
So, often the problem lies in the banal lack of gas. Some users forget to turn on the gas supply. In this case, everything will work as soon as the gas supply tap is opened.
Another popular reason is overlap pipeline through which water is supplied. After you open the water supply, the gas water heater will operate as before.
In some cases the problem lies in batteries. Perhaps they are installed incorrectly or have already shrunk. In this case, you need to check the batteries and make sure that they are installed correctly and nothing is mixed up, or replace dead batteries, if such a need arises.
Problem #2 - the water heats up too low
This malfunction may be due to insufficient gas pressure. Here it is enough to increase the flow using the regulator.
Often the water does not heat up well due to the fact that the water supply is set to maximum. In this case, you need to reduce the flow rate using the same regulator.
Problem #3 - the burner does not work or goes out
If your burner does not light and, accordingly, the gas water heater does not work normally Electrolux, then you first need to carefully check the chimney duct.Most often the problem lies in the chimney. Debris could have gotten into it. Because of this, the protection systems are activated, after which the gas supply is shut off.
If a blockage is detected, you will have to clean it chimney pipe. This is a difficult task, but you can do the job yourself. Otherwise, you will have to call a specialist.
Another reason is weak pipeline pressure. You need to check the water pressure in all taps. It is possible that the cause of the breakdown lies in poor operation of the general water supply network. By increasing the water flow, you will get rid of this problem.
Faulty water unit
Also, the burners in the column often go out due to a breakdown of the water unit. This problem is one of the most common. Usually the cause of failure is associated with membrane wear, filter clogging, and plaque formation. To find and fix it, you have to disassemble the unit, clean everything, replace the membrane if necessary.
Quite often, it is the formation of plaque that causes the breakdown of the water unit. Plaque appears on the water block rod. Over time, it leads to rubbing of the oil seal.
Sometimes plaque forms due to poor quality water. A similar problem will haunt you all the time if you cannot improve the quality of the water used in the gas water heater. To solve this problem, you can set filters.
The gas water heater keeps going out
If the column lights up and then immediately goes out, then you need to adjust the water supply mode - both cold and hot. Do not turn on cold water at the same time as hot water. You need to use the regulator to set the water temperature so that the column operates normally again.
Igniter may go out due to the fact that the device solenoid valve faulty. Often problems arise due to oxidation of contacts or thermocouple failure.
A faulty system thermostat can also lead to similar consequences as a broken one. gas valve.
Often, after installing the gas handle, it is impossible to light the pilot light. This problem occurs due to improper installation of the spark plug. There may also be some dirt on it. In this case, the spark plug needs to be cleaned and reinstall in a different position.
Problem #4 - you hear a popping sound when you turn it on
Popping is another pressing problem that worries many users. Usually the reason for popping noises is that the draft in the chimney is too weak. A possible option is a faulty ignition retarder. It is best to replace it with a new one.
If we are talking about a gas water heater equipped with a wick, then the cause of the malfunction lies in the incorrect position of the wick flame.
Also, discharged power supplies can also cause popping noises. They have to be replaced. It wouldn't hurt to test microswitch in the water block (if you press it with your hand, there should be a spark) and checking the position of the spark plug.
Problem #5 - heat exchanger failure
The heat exchanger often breaks down due to the fact that the user of the gas water heater does not comply with operating rules equipment. Frequent causes of radiator failure are the formation of scale inside the tubes and small cracks outside.
Scale can be removed by washing the heat exchanger with special means, and cracks (also called “fistulas”) on copper tubes can be treated solder with a gas burner.
It can also fail after incorrect adjustment of the gas valve. In this case, you need to study the instructions and correctly configure the operation of this element.
Each geyser model has its own characteristics, so you need to look for the cause of the problem in each individual case.
Problem #6 - smell of gas in the room
The smell of gas is the most unpleasant problem that poses a health threat. The cause of the smell is a gas leak. You must immediately turn off the water heater and ventilate the room. It would not be superfluous to contact the Ministry of Emergency Situations.
And although most of the listed breakdowns can be fixed on your own, you should not take on too much. For example, do not underestimate the threat posed by gas poisoning. It is recommended to regularly inspect the gas water heater for damage and malfunctions. And if a problem is detected, immediately contact the gas service. This way you will save not only your nerves, but also your health.
How to avoid common breakdowns?
Those who follow the simplest safety rules when operating gas-using equipment will not have to worry about the technical condition of their dispenser.
The simplest tips will help prevent typical breakdowns:
- The gas water heater must be installed out of the reach of children. Otherwise, the child will damage the equipment or be injured.
- Particular attention should be paid to the door in the room where the equipment is installed. There should be a gap (2 cm) under the door. This will be enough for ventilation.
- Directly during operation of the column, it is advisable to open the window, if such an opportunity is provided in the room where it is installed.
- If your water heater is in a room that is not heated (for example, in a summer cottage), then in winter all remaining water should be removed from the water heater.
- Some parts of the geyser structure become very hot, so touching them is dangerous - you can get burned.
- Under no circumstances should clotheslines be tied to gas pipes and clothes dried on them. Access to gas pipes should be extremely simple.
If you use the column for a long time, then you need to regularly check the chimney draft.
Adjusting the geyser Electrolux
First, you need to come to terms with the fact that you need to entrust the installation of the column to a specialist. If you install this equipment yourself, the service center may refuse warranty service, as many manufacturers warn about.
There are requirements for rooms in which a gas water heater can be installed. The area of such a room should not be less than 12 square meters. m. Ceiling height - at least 2.2 m. There must be vents or opening windows. If you do not have such a room, then installing a gas water heater is not allowed.
However, many problems arise precisely because of insufficiently competent installation and adjustment of the gas water heater, so you must carefully monitor the work of the installation technician. If it seems to you that he is ignoring the rules described in SNiP 2.04.08-87 , then you should call another specialist for installing geysers.
The very first launch is possible only in the presence of an inspector from the gas service. It is prohibited to connect the speaker yourself, as stated in Section 88(1) VIII Decree of the Government of the Russian Federation N 410 dated 05/14/2013 (update date 01/01/2019) “On measures to ensure safety when using... gas equipment.” This must be carried out by a qualified specialist.
Correct speaker setup
Breakdowns often appear after improper equipment setup. In order to adjust the operating mode of the equipment, you need to use the display, which is equipped with almost all speakers Electrolux. This display is connected to a sensor that monitors the water temperature.
In order to change the power, you need to change the intensity of the fire.A display with indicators will help you with this. In some geysers Electrolux (with flame modulation) you need to set the desired water heating temperature. This is how the operation of the equipment is adjusted. After this, the burner power will change.
Remember that you can only adjust the temperature in the specified way. If you mix cold water with hot water, you will only aggravate the situation and ruin the gas water heater.
Gas equipment cleaning
You can avoid many breakdowns by using regular maintenance and cleaning individual elements of the column structure that are most susceptible to contamination. In geysers from this manufacturer, such parts include the burner and heat exchanger.
Burner jets often become clogged due to soot, and scale often appears inside the heat exchanger. Carbon deposits can be seen on the outside of the heat exchanger.
You can clean the device yourself only if the warranty has already expired. Otherwise, you should call the service center, because during the warranty period, specialists will remove all dirt for free.
If the warranty has already expired, then you need to remove the column casing, remove the heat exchanger and remove the burner. The tubes inside can be washed using conventional chemicals, and the radiator fins outside can be washed with a regular solution (soap). It is recommended to clean the burner using a metal awl.
Gas water heater security system
Every speaker released by "Electrolux“, is equipped with a multi-level security system.It is designed to prevent gas and water leaks. When the pressure increases, the protection system should work and turn off the column.
Of all the malfunctions, the greatest threat is caused by breakdowns that lead to gas leaks, so it is recommended to give preference to models with an automatic shutdown function. We also recommend that you read causes of geyser explosion.
Conclusions and useful video on the topic
What to do if the Electrolux brand column does not turn on when the water pressure is low:
Recommendations for repairing Electrolux brand speakers with your own hands:
A typical connection of Electrolux geysers is shown in the following video:
And although repairing any geyser Electrolux You can do it yourself, but you shouldn’t do it if the warranty period has not yet expired.
Particular attention should be paid to breakdowns that lead to gas leaks. This is extremely dangerous - in such a situation, it would be right to seek qualified help. In other cases, you can carry out repairs yourself..
Do you know almost everything about breakdowns, their diagnosis and solutions and want to share useful information with other users? Or would you like to supplement the list of faults discussed above with another, no less popular one, which we have not mentioned? Write your comments in the block below.
Periodically the column starts 3-4 times. The electric valve clicks are heard, but the dispenser does not start. Column Nano pro 2.0
The COLUMN starts sparking and turns on 1-2 minutes after opening the water, sometimes it doesn’t turn on at all due to the lack of a spark, despite the fact that the water and gas pressure is good and the Durussell batteries are fresh. Column - Electrolux GWN 10 NanoPlus 2.0, service life 7 months. This problem is already 2 months old.
When launched from the window, the fire enters the front panel. What to do?